Advertisement
Oral and Maxillofacial Radiology| Volume 93, ISSUE 4, P483-487, April 2002

Use of imaging guides in preimplant tomography

      Abstract

      Objectives. The objective of this study was to quantify the variation in use and type of imaging guides used by community-based specialists and general practitioners during dental implant treatment planning phases. The specific aim of this study was to test the hypothesis that specialists are more likely to use some form of cross-sectional imaging in conjunction with imaging guides during the preoperative assessment of dental implant procedures. Study Design. Records from 630 patients with implants (1640 implants) referred for cross-sectional tomography were reviewed. Imaging guide type and implant sites were noted. Results. The distribution of referring dentists by specialty was as follows: general practitioners (42.2%), periodontists (35.1%), oral and maxillofacial surgeons (13.3%), and prosthodontists (7%). Of patients referred for tomograms, 52% were referred without a surgical guide. Conclusion. Specialists ordered tomograms in conjunction with imaging guides more often than did general practitioners. Prosthodontists and periodontists preferred to use more restrictive guides than did general practitioners or oral and maxillofacial surgeons. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2002;93:483-7)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      References

        • Pietrokovski J
        The bony residual ridge in man.
        J Prosthet Dent. 1975; 34: 456-462
        • Clark DE
        • Danforth RA
        • Barnes RW
        • Burtch ML
        Radiation absorbed from dental implant radiography: a comparison of linear tomography, CT scan, and panoramic and intra-oral techniques.
        J Oral Implantol. 1990; 16: 156-164
        • Grondahl K
        • Ekestubbe A
        • Grondahl HG
        • Johnsson T
        Reliability of hypocycloidal tomography for the evaluation of the distance from the alveolar crest to the mandibular canal.
        Dentomaxillofac Radiol. 1991; 20: 200-204
        • Petersson A
        • Lindh C
        • Carlsson LE
        Estimation of the possibility to treat the edentulous maxilla with osseointegrated implants.
        Swed Dent J. 1992; 16: 1-6
        • Fredholm U
        • Bolin A
        • Andersson L
        Preimplant radiographic assessment of available maxillary bone support. Comparison of tomographic and panoramic technique.
        Swed Dent J. 1993; 17: 103-109
        • Weinberg LA
        CT scan as a radiologic data base for optimum implant orientation.
        J Prosthet Dent. 1993; 69: 381-385
        • Lam EW
        • Ruprecht A
        • Yang J
        Comparison of two-dimensional orthoradially reformatted computed tomography and panoramic radiography for dental implant treatment planning.
        J Prosthet Dent. 1995; 74: 42-46
        • Tyndall AA
        • Brooks SL
        Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial Radiology.
        Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000; 89: 630-637
        • Petrikowski CG
        • Pharoah MJ
        • Schmitt A
        Presurgical radiographic assessment for implants.
        J Prosthet Dent. 1989; 61: 59-64
        • Kassebaum DK
        • Nummikoski PV
        • Triplett RG
        • Langlais RP
        Cross-sectional radiography for implant site assessment.
        Oral Surg Oral Med Oral Pathol. 1990; 70: 674-678
        • Modica F
        • Fava C
        • Benech A
        • Preti G
        Radiologic-prosthetic planning of the surgical phase of the treatment of edentulism by osseointegrated implants: an in vitro study.
        J Prosthet Dent. 1991; 65: 541-546
        • Israelson H
        • Plemons JM
        • Watkins P
        • Sory C
        Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients.
        Int J Periodontics Restorative Dent. 1992; 12: 52-61
        • Mecall RA
        • Rosenfeld AL
        The influence of residual ridge resorption patterns on implant fixture placement and tooth position. 2. Presurgical determination of prosthesis type and design.
        Int J Periodontics Restorative Dent. 1992; 12: 33-51
        • Almog DM
        • Onufrak JM
        • Hebel K
        • Meitner SW
        Comparison between planned prosthetic trajectory and residual bone trajectory using surgical guides and tomography–-a pilot study.
        J Oral Implantol. 1995; 21: 275-280
        • Almog DM
        • Sanchez R
        Correlation between planned prosthetic and residual bone trajectories in dental implants.
        J Prosthet Dent. 1999; 81: 562-567